Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Infect Dis ; 224(11): 1849-1860, 2021 12 01.
Article in English | MEDLINE | ID: covidwho-1612585

ABSTRACT

T-cell immunity associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection or vaccination in solid organ transplant recipients (SOTRs) is poorly understood. To address this, we measured T-cell responses in 50 SOTRs with prior SARS-CoV-2 infection. The majority of patients mounted SARS-CoV-2-specific CD4+ T-cell responses against spike (S), nucleocapsid, and membrane proteins; CD8+ T-cell responses were generated to a lesser extent. CD4+ T-cell responses correlated with antibody levels. Severity of disease and mycophenolate dose were moderately associated with lower proportions of antigen-specific T cells. Relative to nontransplant controls, SOTRs had perturbations in both total and antigen-specific T cells, including higher frequencies of total PD-1+ CD4+ T cells. Vaccinated SOTRs (n = 55) mounted significantly lower proportions of S-specific polyfunctional CD4+ T cells after 2 doses, relative to unvaccinated SOTRs with prior coronavirus disease 2019. Together, these results suggest that SOTRs generate robust T-cell responses following natural infection that correlate with disease severity but generate comparatively lower T-cell responses following mRNA vaccination.


Subject(s)
COVID-19 Vaccines/immunology , COVID-19/immunology , T-Lymphocytes/immunology , Transplant Recipients , Humans , Immunity, Cellular , Organ Transplantation , SARS-CoV-2 , Vaccination
2.
Ann Intern Med ; 175(2): 226-233, 2022 02.
Article in English | MEDLINE | ID: covidwho-1579921

ABSTRACT

BACKGROUND: COVID-19 is more severe in transplant recipients. Variants of concern have supplanted wild-type virus. In transplant recipients, data are limited on 2-dose or 3-dose vaccine immunogenicity against variant viruses. OBJECTIVE: To assess neutralizing antibody responses against SARS-CoV-2 variants in transplant recipients after 2 and 3 vaccine doses. DESIGN: Secondary analysis of a randomized, double-blind, controlled trial of a third dose of mRNA-1273 vaccine versus placebo. (ClinicalTrials.gov: NCT04885907). SETTING: Single-center transplant program. PATIENTS: Organ transplant recipients. INTERVENTION: Third dose of mRNA-1273 vaccine versus placebo. MEASUREMENTS: Sera were analyzed for neutralization against wild-type virus and the Alpha, Beta, and Delta variants using a surrogate virus neutralization assay and a spike-pseudotyped lentivirus assay. RESULTS: A total of 117 transplant recipients were analyzed (60 in the mRNA-1273 group and 57 in the placebo group). Sera were obtained before and 4 to 6 weeks after the third dose. After 2 doses, the proportion of patients with positive neutralization for all 3 variants was small compared with wild-type virus. After the third dose of mRNA-1273 vaccine, the proportion with a positive neutralization response versus placebo was improved for all 3 variants as measured by both assays. Based on the pseudovirus neutralization assay against the Delta variant, 33 of 60 (55%) patients were positive in the mRNA-1273 group versus 10 of 57 (18%) in the placebo group (difference, 37 [95% CI, 19 to 53] percentage points). The differences were 36 (CI, 17 to 51) percentage points for the Alpha variant and 31 (CI, 15 to 46) percentage points for the Beta variant. In the mRNA-1273 group, lower neutralization values were observed for variants compared with wild-type virus, especially the Beta variant. LIMITATIONS: There is no clear correlate of protection for neutralizing antibody. This was a secondary analysis. CONCLUSION: In organ transplant recipients, a third dose of mRNA vaccine increases neutralizing antibody response against SARS-CoV-2 variants compared with placebo. PRIMARY FUNDING SOURCE: Ajmera Transplant Centre.


Subject(s)
2019-nCoV Vaccine mRNA-1273/administration & dosage , Antibodies, Neutralizing/blood , COVID-19/immunology , COVID-19/prevention & control , Organ Transplantation , SARS-CoV-2 , Transplant Recipients , 2019-nCoV Vaccine mRNA-1273/adverse effects , Aged , COVID-19/virology , Double-Blind Method , Female , Humans , Immunocompromised Host , Male , Middle Aged
4.
Am J Transplant ; 21(12): 3980-3989, 2021 12.
Article in English | MEDLINE | ID: covidwho-1341238

ABSTRACT

Solid organ transplant recipients are at high risk of severe disease from COVID-19. We assessed the immunogenicity of mRNA-1273 vaccine using a combination of antibody testing, surrogate neutralization assays, and T cell assays. Patients were immunized with two doses of vaccine and immunogenicity assessed after each dose using the above tests. CD4+ and CD8+ T cell responses were assessed in a subset using flow-cytometry. A total of 127 patients were enrolled of which 110 provided serum at all time points. A positive anti-RBD antibody was seen in 5.0% after one dose and 34.5% after two doses. Neutralizing antibody was present in 26.9%. Of note, 28.5% of patients with anti-RBD did not have neutralizing antibody. T cell responses in a sub-cohort of 48 patients showed a positive CD4+ T cell response in 47.9%. Of note, in this sub-cohort, 46.2% of patients with a negative anti-RBD, still had a positive CD4+ T cell response. The vaccine was safe and well-tolerated. In summary, immunogenicity of mRNA-1273 COVID-19 vaccine was modest, but a subset of patients still develop neutralizing antibody and CD4+T- cell responses. Importantly polyfunctional CD4+T cell responses were observed in a significant portion who were antibody negative, further highlighting the importance of vaccination in this patient population. IRB Statement: This study was approved by the University Health Network Research Ethics Board (CAPCR ID 20-6069).


Subject(s)
COVID-19 , Organ Transplantation , Antibodies, Neutralizing , Antibodies, Viral , COVID-19 Vaccines , Humans , Immunity, Cellular , Organ Transplantation/adverse effects , SARS-CoV-2
5.
J Appl Lab Med ; 7(1): 57-65, 2022 01 05.
Article in English | MEDLINE | ID: covidwho-1338715

ABSTRACT

BACKGROUND: In North America, both messenger RNA (mRNA) vaccines, Pfizer-BioNTech BNT162b2, and Moderna mRNA-1273, each utilizing a 2-dose regimen, have started to be administered to individuals. METHODS: We evaluated the quantitative serologic antibody response following administration of either a single dose or both doses of an mRNA severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine in a cohort of 98 participants (88 healthcare workers [HCW] and 10 solid organ transplant [SOT] recipients). Antibody levels were compared across 3 immunoassays: Elecsys Anti-SARS-CoV-2 S (Roche Diagnostics), SARS-CoV-2 TrimericS IgG (DiaSorin), and SARS-CoV-2 IgG II Quant (Abbott). RESULTS: Among HCW, sensitivity ranged from 100% (Roche), 99% (Abbott) and 98% (DiaSorin). The SARS-CoV-2 IgG II Quant and SARS-CoV-2 TrimericS IgG assays showed good agreement with a Pearson correlation coefficient of R = 0.95. Pearson correlation coefficients of R = 0.82 and 0.83 were obtained for Elecsys Anti-SARS-CoV-2 S vs SARS-CoV-2 TrimericS IgG and SARS-CoV-2 IgG II Quant vs Elecsys Anti-SARS-CoV-2 S, respectively. Significant differences in antibody levels between HCW and SOT recipients were observed. A decrease in antibody levels from time of vaccine administration to blood draw was evident. Among those with a second dose, an increase in antibody levels with increased time between administration of the first and second dose was observed. CONCLUSIONS: The absolute values generated from each of the assay platforms are not interchangeable. Antibody levels differed with increased time between vaccine administration and with increased time between administration of the first and second dose. Further, significant differences in antibody levels between HCW and SOT recipients were observed.


Subject(s)
COVID-19 , SARS-CoV-2 , 2019-nCoV Vaccine mRNA-1273 , BNT162 Vaccine , COVID-19 Vaccines , Humans , Immunoassay
6.
Transplantation ; 105(10): 2175-2183, 2021 10 01.
Article in English | MEDLINE | ID: covidwho-1276293

ABSTRACT

BACKGROUND: Several studies have described the clinical features of COVID-19 in solid-organ transplant recipients. However, many have been retrospective or limited to more severe cases (hospitalized) and have not routinely included serial virological sampling (especially in outpatients) and immunologic assessment. METHODS: Transplant patients diagnosed with COVID-19 based on a respiratory sample PCR were prospectively followed up to 90 d. Patients provided consent for convalescent serum samples and serial nasopharyngeal swabs for SARS-CoV-2 antibody (antinucleoprotein and anti-RBD) and viral load, respectively. RESULTS: In the 161 SOT recipients diagnosed with COVID-19, the spectrum of disease ranged from asymptomatic infection (4.3%) to hospitalization (60.6%), supplemental oxygen requirement (43.1%), mechanical ventilation (22.7%), and death (15.6%). Increasing age (OR, 1.031; 95% CI, 1.001-1.062; P = 0.046) and ≥2 comorbid conditions (OR, 3.690; 95% CI, 1.418-9.615; P = 0.007) were associated with the need for supplemental oxygen. Allograft rejection was uncommon (3.7%) despite immunosuppression modification. Antibody response at ≥14 d postsymptoms onset was present in 90% (anti-RBD) and 76.7% (anti-NP) with waning of anti-NP titers and stability of anti-RBD over time. Median duration of nasopharyngeal positivity was 10.0 d (IQR, 5.5-18.0) and shedding beyond 30 d was observed in 6.7% of patients. The development of antibody did not have an impact on viral shedding. CONCLUSIONS: This study demonstrates the spectrum of COVID-19 illness in transplant patients. Risk factors for severe disease are identified. The majority form antibody by 2 wk with differential stability over time. Prolonged viral shedding was observed in a minority of patients. Reduction of immunosuppression was a safe strategy.


Subject(s)
Antibodies, Viral/blood , COVID-19/immunology , Organ Transplantation , SARS-CoV-2 , Viral Load , Adult , Aged , COVID-19/virology , Female , Humans , Male , Middle Aged , Prospective Studies , Severity of Illness Index , Transplant Recipients , Virus Shedding
SELECTION OF CITATIONS
SEARCH DETAIL